Telefonische Beratung: +497151 - 2564811

  Transport & Store Lithium-Ion Batteries Safely

  06/03 - 06/05: LionCare @ BatteryShow Europe

CEMO fireproof battery charging cabinet Premium Plus 8/10 - 1 /3-phase

€5,521.60 *

incl. VAT.
Please note: Notes on delivery time

Free shipping (Germany, mainland)!

Shippingtime: 5-6 weeks

Stacking feet / castors:

Integrated socket strips:

  • CEMfALPP810mF13

Questions about the article?
Our staff member Ingo Jüstel is happy to help you:
+49 (0) 7151 - 256 4811 or info@lion-care.com

Size, structure and function of the storage cabinet This version of the CEMO battery... more
"CEMO fireproof battery charging cabinet Premium Plus 8/10 - 1 /3-phase"
Charging function: Yes
Installation site: Inside
Fireproof: Yes
Fire resistance: 60 min
Fire test procedure: inside to outside
Cabinet type: Floor cabinet
Number of doors: 2 doors
Number of drawers: 0
Number of shelves: 1
Power supply: 2 Leisten á 6 x 230 V / 50 Hz
External dimensions: 890 x 660 x 1110 mm
Internal dimensions: 730 x 530 x 880 mm
Weight: 136 kg
 

Size, structure and function of the storage cabinet

This version of the CEMO battery charging cabinet is a storage and charging system. The external dimensions are 890 x 660 x 1110 mm (1-phase) or 950 x 660 x 1110 mm (3-phase), the internal dimensions 730 x 530 x 880 mm, the weight 136 kg.

Direct comparison of the CEMO 8/10 variants

  CEMO 8/10 Storage CEMO 8/10 Basic CEMO 8/10 Premium CEMO 8/10 Premium Plus
External dimensions 800 x 660 x 1110 mm 800 x 660 x 1110 mm 890 x 660 x 1110 mm 890 x 660 x 1110 mm
Internal dimensions 730 x 530 x 910 mm 730 x 530 x 840 mm 730 x 530 x 880 mm 730 x 530 x 880 mm
Empty weight 132 kg 136 kg 136 kg 136 kg
Loading function No Yes Yes Yes
Power supply /

1-phase: 230 V

3-phase: 400 V

1-phase: 230 V

3-phase: 400 V

1-phase: 230 V

3-phase: 400 V

Warning system acoustic, battery-operated acoustic, battery-operated

acoustic, current-operated

Connection option via potential-free contact

(accessories: acoustic + optical)

acoustic, current-operated

Can be connected via potential-free contact

Remote alerting via cell phone

(accessory: acoustic + optical)

Stackable Yes (max. 2-fold) Yes (max. 2-fold) Yes (max. 2-fold) Yes (max. 2 compartments)

Differences to the Basic charging cabinet

In contrast to the CEMO Basic 8/5 battery charging cabinet, the smoke detector in this variant is powered by electricity. In addition, however, the currentless circuit is also included for smoke detection, a potential-free output for connection to the fire alarm system on the outside of the cabinet, as well as a 12V connection option for accessories such as a combination alarm unit (optical and acoustic).

In addition to the Premium version

The Premium Plus version of the CEMO battery charging cabinets also has an integrated interior temperature display and remote alerting to a cell phone (using a SIM card). Additional functions are also possible via remote access.

Features

In the premium version, the charging cabinet has an alarm system, a smoke detector with potential-free output for an alarm signal and a technical ventilation system. If heat and/or smoke develops, the power circuit is interrupted. If the door is opened, the power supply is also interrupted by means of a door contact switch. The doors should therefore always be closed during the charging process.

These are charging variants with 2 vertically arranged 6-socket power strips for the power supply. Either with a 230 V version with 1-phase power supply (3500 W / 16 A) or the 400 V version with 3-phase power supply (2x 3500 W / 2x 16 A). Please note that the product images still show the previous version with 4-way socket strips.

In the premium version, the charging cabinet has an acoustic warning tone, heat dissipation during charging with the aid of the built-in fan and a charging stop in the event of a fault or damage. If heat builds up, the power circuit is interrupted by a power-off circuit. If the door is opened, the power supply is also interrupted by means of a door contact switch. The doors should therefore always be closed during the charging process. In addition, the Premium version has an improved connection option for combination alarm devices (12V) and a connection to a fire alarm system.

Tested according to VDMA up to 6 kW/h

The battery cabinet has been tested for lithium-ion batteries in accordance with VDMA. The maximum permissible energy density for this system is 6.0 kWh.

VDMA 24994 is a test standard specifically for fire-resistant storage cabinets designed to safely store lithium-ion batteries. It tests whether the cabinet can withstand a thermal runaway, i.e. dangerous overheating and spontaneous combustion of the battery. It is important that the cabinet does not emit any flames or toxic gases to the outside and that the door does not open under pressure. The standard helps companies to significantly increase safety when storing lithium-ion batteries and is considered an important benchmark that is increasingly recognized by manufacturers and insurers.

MPA-tested fire resistance over 60 minutes from the inside to the outside

Furthermore, a fire test was carried out for this system in accordance with EN 1363-1, in which a fire resistance of 60 minutes from the inside to the outside was verified.

Equipped with the CEMO lockEX lock

CEMO lockEX is an innovative mechanism in the door lock that reliably relieves the pressure of flammable gases inside the enclosure in a controlled manner to effectively prevent explosions.

The design is based on an intelligent spring mechanism which, in the event of a damaged Li-battery exploding, gently opens the enclosure doors to release the resulting pressure and then immediately closes them securely again.

The protection granted by the German Patent and Trademark Office is particularly important here. It has long been known among experts that lithium batteries can not only cause flames and explosive burning of individual cells, but also a gas explosion due to leaking cell vapors. This is the worst case scenario in the event of a battery fire, as it can nullify the entire protective effect in case of doubt and can therefore be the most decisive criterion in the risk assessment.

CEMO lockEX combines fire protection and explosion protection in one product and offers a reliable solution for dealing with potentially dangerous battery fires.

The lockEX technology effectively interrupts the progress of a battery fire. An explosion can occur even before a thermal runaway begins. If the enclosure housing gives way or the doors open, the protective effect can be lost immediately and the burning cells and battery packs are propelled unhindered into the environment at the installation site.

CEMO's lockEX mechanism ensures that the explosion pressure that builds up inside the enclosure is effectively managed. This advanced NO-BANG technology ensures that protection is fully maintained, even in the worst-case scenario of a battery fire.

Up to 3-phase

The 3-phase version is required if, for example, batteries are to be charged with fast chargers that have a greater power requirement than the 1-phase version can provide.

Well equipped in the event of an accident

Critically damaged lithium-ion cells in particular can pose a serious risk to people and equipment in the event of a fire ("thermal runaway"). Dust caused by these fires can settle on the circuit boards of production and operating devices and damage them permanently. This charging cabinet has an MPA-tested fire resistance over 60 minutes from the inside to the outside in accordance with DIN EN 1363-1. A real battery fire test was carried out with an independent university. The air inlet and outlet openings close automatically in the event of fire. However, the doors should always remain closed during use.

Robust construction

The charging cabinet is made of robust, fire-resistant components. Special fire protection seals prevent flames from escaping and it has a cold smoke-tight closure system for the openings. The doors are double-leaf and lockable with sturdy locking and suspension. the doors are painted in orange, similar to RAL 2004, and the body in gray, similar to RAL 7035.

Portable use

The container can be stacked to a height of 3 units. The stacking feet make it possible to drive underneath. As an option, the container can also be fitted with an additional, fire-resistant and tested cable gland, for example to connect to the in-house fire alarm system.

Guidelines

There are currently no legal regulations for the storage of lithium batteries / lithium-ion batteries. Only VdS Schadenverhütung GmbH issues general safety rules for damage prevention in its publication VdS 3103 : 2019-06 (03), and it is advisable to clarify your requirements with your property insurance company in advance.


The manufacturer

CEMO GmbH from Weinstadt has stood for safe storage with imagination and energy for more than 60 years. The company is a pioneer in the field of modern transportation and storage container technology and is one of the market leaders in this area.

Future-oriented

Lithium-ion batteries will be indispensable in all industrial applications in the coming years. However, if used improperly, batteries can pose a potential hazard during production, storage and transportation that should not be underestimated. By purchasing this storage cabinet, you protect yourself against major financial losses right from the start.

In use for you

If you have any questions, please do not hesitate to contact us. We look forward to hearing from you!

Charging function: Yes
Outer width: 60 - 80 cm
Outer height: 100 - 200 cm
Installation site: Inside
Fireproof: Yes
Fire resistance: 60 min
Fire test procedure: inside to outside
Cabinet type: Floor cabinet
Number of doors: 2 doors
Number of drawers: 0
Number of shelves: 1
Power supply: 2 Leisten á 6 x 230 V / 50 Hz
External dimensions: 890 x 660 x 1110 mm
Internal dimensions: 730 x 530 x 880 mm
Weight: 136 kg
CEMO battery charging cabinets - Charge batteries safely! more

CEMO battery charging cabinets - Charge batteries safely!

Comparison of charging cabinets and safety cabinets for Li-ion batteries The table below shows... more

Comparison of charging cabinets and safety cabinets for Li-ion batteries

The table below shows the most important features and differences between battery charging cabinets and fireproof safety cabinets for Li-ion batteries.

 Battery charging cabinets
(Features vary depending on the model)
Safety cabinets for rechargeable batteries
(Features vary depending on the model)
Primary purpose Storage and charging of Li-ion batteries / battery-operated end devices Storage of intact and defective Li-ion batteries while protecting the environment
Power connection Always available Partly available, partly retrofittable
Power supply Variable (230V, USB etc.);
many configurations possible
Usually 230V sockets; number and placement depending on model
Access protection Lock, KeyCode, RFID code etc. Lock
Fire resistance capability None F30 / F90, dedicated fire tests
Safety & warning mechanisms None Exhaust air systems, warning alarms, automatically closing doors
Designs / cabinet shape Floor cabinet, underbench cabinet
Number of door leaves 1 or 2 door leaves
Type of doors Sheet steel, some with viewing window Safety / fire doors
Interior fittings Shelves Drawers, shelves, pull-outs
  To the
battery charging cabinets
To the fireproof safety cabinets for batteries
FAQ
Fragen & Antworten zum Artikel ... mehr
Kann ich Batterie-Ladeschränke im Freien / Lagerhalle / Garage aufstellen?

Standard-Sicherheitsschränke sind für den Innenbereich konzipiert, so dass eine Nutzung im Außenbereich nicht möglich ist.
Die Brandschutzplatten, die in den Schränken verbaut sind, enthalten Gips, der sehr viel Wasser enthält, welches sich bei Frost ausdehnt. Dadurch werden die Platten verformt. Es kann nicht mehr gewährleistet werden, dass ein solcher Schrank noch dicht ist oder einer Explosion standhalten kann.

Wann kann ich einen Akkuschrank ohne Feuerwiderstandsfähigkeit kaufen?

Wenn Sie bereits über einen geeigneten Raum verfügen, der baulich feuerbeständig ist, dann benötigen Sie nicht zwangsweise einen Sicherheitsschrank, der den Brand eindämmt.

Bitte vergessen Sie jedoch nicht, dass die Schäden durch einen Akkubrand immense und auch giftige Verunreinigungen mit sich bringen, deren Entsorgung schnell zu hohen Kosten führen kann.

Darüber hinaus können Sie möglicherweise bis zur endgültigen Behebung des Schadens – je nach Schadensort - nicht wie gewohnt weiterarbeiten.

Last viewed