Technical data
| Alarm forwarding: | Yes |
|---|---|
| Cabinet Power Supply: | 230 V / AC |
| Fire protection class: | F90 |
| Fire suppression: | With |
| Fire test procedure: | DIN EN 1363-1, DIN EN 14470-1 |
| Integrated power strips: | Without |
| Internal dimensions (mm): | 1 620 x 490 x 410 |
| Load function: | Optional |
| Material: | Steel |
| Number of doors: | 1-leaf hinged |
| Outer dimensions (mm): | 2 050 x 635 x 620 |
| Place of deployment: | Indoor area |
| Wardrobe type: | Freistehender Schrank |
| Weight (kg): | 297 |
Product information „ECOSAFE M - Storage/charging cabinet, 1-door.“
Overview
The ECOSAFE M is a high-quality safety cabinet for the storage and optional charging of lithium-ion batteries. Developed for professional use, it reliably protects against the risks of thermal runaway and reduces potential damage to persons, buildings, and operational facilities.
With tested fire resistance of 90 minutes (Type 90) as well as standard-compliant fire tests, the cabinet offers comprehensive protection both from inside to outside and from outside to inside. This prevents a battery fire from spreading to the surroundings or external fires from affecting the cabinet contents.
The body consists of a high-quality steel construction with double heat-insulated triple walls. Integrated thermal insulation panels reduce thermal bridges, while the exterior surfaces are protected by a durable epoxy coating. The interior lining with melamine panels additionally provides a robust, chemically resistant, and easy-to-clean surface.
The robust design, combined with modular interior fittings as well as optionally integrable safety, alarm, and charging systems, makes the ECOSAFE M a flexible and future-proof solution for modern battery storage concepts.
Scope of delivery
- Single-door safety cabinet (floor-standing cabinet, steel construction)
- 4 perforated shelves for structured storage
- Integrated spill tray in the base area
- Preparation for electrical equipment (cable feed-through and connection options)
- Mechanical basic equipment for safe operation
- Fire suppression system
- Alarm systems (optical smoke detector, beacon light, alarm sound, potential-free contact)
- 230 V power connection
Technical data
- External dimensions (H × W × D): 2,050 × 635 × 620 mm
- Internal dimensions (H × W × D): 1,620 × 490 × 410 mm
- Weight: approx. 297 kg
- Material: steel
- Design: floor-standing cabinet, single-door
- Number of shelves: 4 (each with up to 50 kg load capacity)
- Installation location: indoor area
- Fire resistance: 90 minutes (Type 90)
- Fire test procedure: DIN EN 1363-1, DIN EN 14470-1
- Charging function: optionally retrofittable
- Power supply: 230 V
Fire suppression
The optionally available fire suppression system is used for the active suppression of an incipient fire inside the cabinet.
How it works:
- Automatic triggering in the event of critical temperature development (79° C)
- Release of an extinguishing or inerting agent in the interior
- Interruption of the oxygen supply or cooling of the fire source
- Prevention of fire spread to other batteries
This system reduces the intensity of a battery fire and significantly limits consequential damage.
Alarm systems
Additional alarm modules can be integrated for the early detection and forwarding of hazards.
Functional scope:
- Detection of smoke or critical temperature rise inside the cabinet
- Visual and acoustic warning signals for direct hazard indication
- Forwarding of alarms to external systems (e.g. building management system or fire alarm control panel)
- Increased response speed during unattended operation
In the corresponding configuration, the safety cabinet is equipped with:
- an optical smoke detector for early fire detection
- a visual alarm indicator (beacon light)
- an acoustic alarm signal (alarm sound)
Connection to an external fire alarm infrastructure is made via a control box with a potential-free contact. This allows a direct connection to the fire alarm control panel (FACP).
The electrical cable routing is structurally integrated:
The cables are routed within the rear wall of the cabinet and exit in a protected manner on the roof of the safety cabinet. This ensures safe, clear, and installation-friendly integration into existing safety systems.
Charging function / Power connection (230 V)
The ECOSAFE M can be operated as a storage cabinet or a combined storage and charging cabinet.
230 V connection:
- Standard solution
- Connection via integrated power strips (e.g. 8 sockets per level)
- Suitable for typical workshop and service applications
The electrical equipment is integrated via prepared connection areas and should be installed by qualified specialist personnel.
Application area & use
The ECOSAFE M is suitable for professional use in:
- Industrial and production facilities
- Workshops and service centers
- Storage and logistics areas
- Research & development
- E-bike, tool, and battery logistics
The safety cabinet is specially designed for the safe storage of lithium-ion rechargeable batteries and meets the requirements of modern fire protection concepts.
It is particularly suitable for applications where:
- rechargeable batteries must be stored in buildings
- fire protection separation is required
- charging processes are to be controlled and safeguarded
Approvals & safety features
- Type 90 safety cabinet according to EN 14470-1
- Fire test according to DIN EN 1363-1
- Fire resistance from inside to outside and outside to inside
Structural safety features:
- Fire-resistant special construction
- Integrated spill tray for collecting leaking substances
- Robust steel construction for industrial use
- Mechanical door securing for safe closure in the event of fire
Notes on use & operation
- Use exclusively for lithium-ion batteries in accordance with the manufacturer's specifications
- Install indoors in suitable, ventilated rooms
- Use recommended within the framework of a risk assessment
- Regular maintenance and inspection required in accordance with legal regulations
- Electrical installation (for charging function) to be carried out by specialist personnel
For maximum safety, the cabinet should be integrated into a holistic fire protection and safety concept.
For any further questions, we are happy to assist you. Get in touch with us.
| Alarm forwarding: | Yes |
|---|---|
| Cabinet Power Supply: | 230 V / AC |
| Fire protection class: | F90 |
| Fire suppression: | With |
| Fire test procedure: | DIN EN 1363-1, DIN EN 14470-1 |
| Integrated power strips: | Without |
| Internal dimensions (mm): | 1 620 x 490 x 410 |
| Load function: | Optional |
| Material: | Steel |
| Number of doors: | 1-leaf hinged |
| Outer dimensions (mm): | 2 050 x 635 x 620 |
| Place of deployment: | Indoor area |
| Wardrobe type: | Freistehender Schrank |
| Weight (kg): | 297 |