- Max. energy density: 8 kWh
- Includes a ventilation system with an alarm
- without fire suppression
- Integrated power strips with 10 sockets
Do you have some questions about this product?
- Your personal contact person
- Name: Petra Fürbeck
- E-Mail: info@lion-care.com
- Phone: +49 (0) 7151 - 256 4817
Technical data
| Alarm forwarding: | Yes |
|---|---|
| Cabinet type: | Freestanding cabinet |
| Charging function: | Optional |
| Fire resistance: | 90 min |
| Fire suppression: | Optional |
| Fire test procedure: | DIN EN 1363-1, DIN EN 14470-1 |
| Internal dimensions (mm): | 1 004 x 440 x 1 804 |
| Max. energy density (kWh): | 8 |
| Number of doors: | 2-leaf hinged |
| Number of drawers: | 0 |
| Number of shelves: | 4 |
| Outer dimensions (mm): | 1 148 x 591 x 2 148 |
| Place of deployment: | Indoor area |
| Power supply: | 0 / 1 / 2 / 3 / 4 power strip(s) with ten outlets each |
| Refractory: | Yes |
| Weight (kg): | 650 |
Product information „PRIOCAB-Li EI90 2-door freestanding cupboard “
Brief overview
The PRIOCAB-Li EI90 from PRIORIT is a double-door safety cabinet designed for the stationary storage and charging of lithium-ion batteries. With a certified fire resistance of over 90 minutes when exposed to fire from both inside and outside in accordance with DIN EN 1363-1, it supports structural fire protection in industrial, storage and operational areas.
The construction, made from non-combustible Class A2-s1, d0 building material, features tested fire load insulation and a cold-smoke-tight locking system. An integrated smoke detector monitors the interior of the cabinet. If a fire is detected, the control unit issues a visual fault signal and automatically switches off the mechanical ventilation. A signal can be forwarded to an external monitoring centre via a potential-free interface.
The cabinet features four height-adjustable wire mesh shelves and is fitted with a power strip with 10 sockets. The internal layout can be customised using additional wire mesh shelves.
Scope of supply
- PRIOCAB-Li EI90, double-door floor-standing cabinet
- 4 height-adjustable wire mesh shelves
- Smoke detector
- Integrated ventilation system with fan
- Control unit with visual fault indicator
- 1 power strip
- Swivel-lever lock with double-bit cylinder
- All-round fire-resistant seals
- Removable base panel
Technical specifications
- External dimensions (W × D × H): 1,148 × 591 × 2,141 mm
- Internal dimensions (W × D × H): 1,004 × 440 × 1,804 mm
- Weight: approx. 650 kg
- Fire resistance: over 90 minutes from both inside and outside
- Material: Non-combustible building material
- Building material class: A2-s1, d0
- Finish: Light grey, similar to RAL 7035
- Door design: double-leaf, non-self-closing
- Door opening angle: approx. 180°
- Load capacity per grating floor: 75 kg
- Power socket strips: 1
- Total number of sockets: 10
- Ventilation: Mechanical ventilation with automatic shut-off in the event of a fire
- Fire detection: Smoke detector
- Alarm: Visual fault indication
- Alarm transmission: Potential-free interface
- Sealing system: Cold-smoke-tight
- Cable entries: Top and bottom
- Base height: 100 mm
- Wheelchair-accessible: Yes
- Area of use: Indoor
Safety and protection features
The PRIOCAB-Li EI90’s protection concept combines a fire-resistant cabinet design with technical fire detection and monitoring.
In the event of smoke development, the integrated control unit responds with a visual fault indication and automatically switches off the ventilation. The surrounding fire-resistant seals automatically expand when exposed to heat, thereby supporting the fire-resistant compartmentalisation of the cabinet’s interior.
A signal can be transmitted via the potential-free contact, for example to a control centre or an existing safety infrastructure.
Areas of application
The PRIOCAB-Li EI90 is suitable for the stationary storage and charging of lithium-ion batteries in commercial and industrial settings.
Typical applications include:
- Industrial and manufacturing facilities
- Workshops and maintenance areas
- Warehouse and logistics companies
- Service and repair centres
- Public sector organisations and municipal depots
- Research and development facilities
Tests and classifications
- Fire resistance testing: DIN EN 1363-1
- Fire resistance: over 90 minutes when exposed to fire from both inside and outside
- Building material classification: A2-s1, d0
Instructions for use
The PRIOCAB-Li EI90 is not fitted with self-closing doors. During storage and loading, the doors must remain closed to ensure that the intended fire protection function is maintained.
When loading the unit, the permissible shelf loads and the required clearance for ventilation must be observed.
The selection of the appropriate cabinet design should be made taking into account the workplace risk assessment and the requirements of the property insurer. Additional recommendations on damage prevention are contained in VdS 3103.
Optional accessories
- Additional grating shelves: For customising the internal layout
- Custom colour scheme: Special colours available on request
Conclusion
The PRIOCAB-Li EI90 offers a combination of certified fire resistance, integrated fire detection and technical ventilation for the storage and charging of lithium-ion batteries. With up to 40 slots and a flexibly adjustable internal layout, the safety cabinet is suitable for a variety of operational charging requirements.
| Alarm forwarding: | Yes |
|---|---|
| Cabinet type: | Freestanding cabinet |
| Charging function: | Optional |
| Fire resistance: | 90 min |
| Fire suppression: | Optional |
| Fire test procedure: | DIN EN 1363-1, DIN EN 14470-1 |
| Internal dimensions (mm): | 1 004 x 440 x 1 804 |
| Max. energy density (kWh): | 8 |
| Number of doors: | 2-leaf hinged |
| Number of drawers: | 0 |
| Number of shelves: | 4 |
| Outer dimensions (mm): | 1 148 x 591 x 2 148 |
| Place of deployment: | Indoor area |
| Power supply: | 0 / 1 / 2 / 3 / 4 power strip(s) with ten outlets each |
| Refractory: | Yes |
| Weight (kg): | 650 |
Downloads
FAQ
Standard security cabinets are designed for indoor use, so they cannot be used outdoors.
The fire protection panels installed in the cabinets contain gypsum, which contains a lot of water, which expands when frozen. This deforms the panels. It can no longer be guaranteed that such a cabinet is still sealed or can withstand an explosion.
If you already have a suitable room that is structurally fire-resistant, then you do not necessarily need a safety cabinet to contain the fire.
However, please do not forget that the damage caused by a battery fire involves immense and also toxic contamination, the disposal of which can quickly lead to high costs.
In addition, you may not be able to continue working as usual until the damage has been finally repaired - depending on the location of the damage.
Standard security cabinets are designed for indoor use, so they cannot be used outdoors.
The fire protection panels installed in the cabinets contain gypsum, which contains a lot of water, which expands when frozen. This deforms the panels. It can no longer be guaranteed that such a cabinet is still sealed or can withstand an explosion.
If you already have a suitable room that is structurally fire-resistant, then you do not necessarily need a safety cabinet to contain the fire.
However, please do not forget that the damage caused by a battery fire involves immense and also toxic contamination, the disposal of which can quickly lead to high costs.
In addition, you may not be able to continue working as usual until the damage has been finally repaired - depending on the location of the damage.