- Overall dimensions: 6 500 x 3 200 x 2 800 mm
- Individually customizable
Do you have some questions about this product?
- Your personal contact person
- Name: Petra Fürbeck
- E-Mail: info@lion-care.com
- Phone: +49 (0) 7151 - 256 4817
Technical data
| Outer dimensions (mm): | 6 500 x 3 200 x 2 800 |
|---|---|
| Tipping weight (kg): | 500 |
Product information „ecell-guard CARPORT - Automated fire protection “
1. Overview
The ecell-guard Carport System including the BASIC System is a mobile, modular fire protection and quarantine solution for high-voltage and electric vehicles with lithium-ion batteries. It combines a robust, weather-resistant carport structure with the automated ecell-guard BASIC fire protection system and is particularly suitable for technical quarantine areas, workshops, service centres, vehicle logistics facilities as well as industrial and commercial sites.
The integrated safety concept enables the early detection of critical temperature developments and the automatic deployment of the fire containment blanket. In the event of an incident, the blanket is automatically pulled over the vehicle to help contain a potential battery fire and reduce thermal exposure to adjacent areas.
2. Scope of Delivery
The complete system includes:
-
Mobile carport structure made of hot-dip galvanised hollow steel sections
-
Modular connector system
-
Roof membrane made of PVC-coated polyester fabric (PES/PVC), UV-resistant
-
Tensioning system for the roof membrane
-
1 × integrated collision protection
-
4 × heavy-duty swivel castors with brakes
-
ecell-guard BASIC System
-
Fire containment blanket
-
Automatic deployment and release mechanism
-
Linear heat detectors
-
Visual and audible alarm system
-
Outdoor technical cabinet
-
Required control and system components
Optionally available:
-
Side and rear panels made of specialist mesh material
-
Custom printing, e.g. corporate design or warning information
-
Integration of solar panels
-
Wallbox for vehicle charging
3. Areas of Application
The ecell-guard Carport System is particularly suitable for:
-
Quarantine areas for damaged or accident-involved electric vehicles
-
Workshops and service centres
-
Car dealerships and vehicle logistics
-
Industrial and commercial sites
-
Monitoring areas for HV vehicles with abnormal or potentially unstable battery systems
Damaged high-voltage batteries may develop a thermal reaction even after a significant delay. The Carport System provides a defined area for the controlled isolation and monitoring of affected vehicles while combining this with automated fire containment.
Maximum vehicle dimensions:
-
Width: 2.20 m
-
Height: 2.10 m
-
Length: 5.20 m
-
Maximum extended vehicle length / silhouette length: 7.50 m
-
Maximum silhouette width: 5.50 m
For alarm transmission or integration into the site's safety infrastructure, the suitable fire alarm system from ecell-guard is required.
4. Technical Data
-
Length: 6.50 m
-
Width: 3.20 m
-
Height: 2.80 m
-
Weight: approx. 500 kg
-
Electrical connection: 230 V / 20 A
-
Construction: Hot-dip galvanised hollow steel sections
-
Roof: PVC-coated polyester fabric
-
Mobility: 4 heavy-duty swivel castors with brakes
-
Design: Modular
-
Weather-resistant: Yes
-
Corrosion-resistant: Yes
-
Fire protection system: ecell-guard BASIC
-
Fire detection: Linear heat detectors
-
Fire containment: Automatically deployed fire containment blanket
-
Alarm: Visual and audible
-
Technical unit: Outdoor technical cabinet
5. Approvals & Safety Features
The ecell-guard Carport including BASIC System operates according to a three-stage safety principle:
Stage 1 – Detection and Alarm
-
Linear heat detectors
-
Visual and audible alarms
-
Connection to a fire alarm system
-
VdS-certified components
Stage 2 – Automatic Deployment
-
Automatic release of the deployment mechanism
-
Automatic deployment of the fire containment blanket over the vehicle
-
No manual intervention required for deployment
Stage 3 – Fire Containment
-
Local containment of the battery fire
-
Reduction of thermal exposure to adjacent areas
-
Additional response time for emergency and rescue services
-
Helps protect surrounding infrastructure
Additional safety features:
-
Programmable warning and deployment times
-
Multiple deployment sequences can be programmed for installations with several system bays
-
Spacers for defined vehicle positioning
-
Can be integrated into existing fire alarm and safety infrastructure
6. Protection System
The ecell-guard BASIC System, included as part of the complete product, works together with the carport structure to provide the active fire protection solution. Sensors, control system, deployment mechanism and fire containment blanket are coordinated as an integrated system.
When a critical condition is detected, an alarm is triggered. The system then automatically activates the deployment mechanism and pulls the fire containment blanket over the vehicle. The blanket encloses the relevant area of the vehicle and helps limit the spread of flames and heat to the surrounding environment.
The complete system therefore combines the quarantine and monitoring of high-voltage vehicles with automated fire containment.
7. Notes on Use & Operation
-
Designed for use as a quarantine, monitoring and safety area for high-voltage and electric vehicles
-
Carport and BASIC System form a coordinated complete system
-
Installation and commissioning by qualified personnel
-
Connection to an existing fire alarm system is possible
-
Mobile design with heavy-duty castors for repositioning
-
Can be integrated into existing operational safety concepts
-
Site-specific operational and structural requirements must be taken into account
8. System Configuration & Extensions
The complete system consists of:
-
Mobile ecell-guard Carport
-
ecell-guard BASIC System
-
Fire containment blanket
-
Automatic deployment system
-
Sensors and alarm system
-
Outdoor technical cabinet
Optional extensions:
-
Specialist mesh side and rear panels
-
Custom design and printing
-
Solar panels
-
Charging infrastructure / wallbox
9. Future-Oriented Solution
As electric mobility continues to grow, so does the need for suitable quarantine and monitoring areas for damaged or abnormal high-voltage vehicles. The ecell-guard Carport including BASIC System combines a mobile, weather-resistant vehicle bay with automated fire detection and fire containment.
Thanks to its modular design, the system can be integrated into different operational safety concepts and extended with side panels, energy supply solutions or charging infrastructure as required. It is therefore particularly suitable for companies looking to establish a defined and technically monitored quarantine area for electric vehicles.
Write and clean HTML faster with the online HTML editor built for quick document editing.
| Outer dimensions (mm): | 6 500 x 3 200 x 2 800 |
|---|---|
| Tipping weight (kg): | 500 |