CEMO Premium 8/20 LockEX 2.0 charging cabinet

Safety cabinet for lithium-ion batteries

Technical data

Alarm forwarding: Yes
Fire resistance: 60 min
Fire suppression: Without
Fire test procedure: VDMA 24994
Internal dimensions (mm): 730 x 530 x 1 760
Load function: Yes
Maximum energy density (kWh): 12
Number of doors: 2-leaf hinged
Number of drawers: 0
Number of shelves: 6
Outer dimensions (mm): 890 x 660 x 2 130
Place of deployment: Indoor area
Power supply: 4 rails at 9 x 230 V / 50 Hz
Refractory: Yes
Wardrobe type: Freistehender Schrank
Weight (kg): 267

Product information „CEMO Premium 8/20 LockEX 2.0 charging cabinet“

In many cases, limited storage space poses a problem, as there is no room for large safety cabinets for storing lithium-ion batteries, or these are too inflexible if the space available in the warehouse changes at short notice. CEMO offers the ideal solution here, which can be expanded at any time and adapted to the needs of your business.

Please contact us if you would like to receive a customised quote.

Size, structure and function of the battery charging cabinet

This version of the CEMO battery charging cabinet is both a storage and charging cabinet, including a smoke detector. The external dimensions are 890 x 660 x 2130 mm (W x D x H), the internal dimensions are 730 x 530 x 1760 mm, and the weight is 267 kg.

Direct comparison of the CEMO 8/20 variants

CEMO 8/20 CEMO 8/20 Basic CEMO 8/20 Premium
External dimensions 800 x 660 x 2130 mm 800 x 660 x 2130 mm 890 x 660 x 2130 mm
Internal dimensions 730 x 530 x 1820 mm 730 x 530 x 1760 mm 730 x 530 x 1760 mm
Empty weight 266 kg 267 kg 267 kg
Charging function No Yes Yes
Power supply /

1-phase: 230 V

3-phase: 400 V

1-phase: 230 V

3-phase: 400 V

Warning system Acoustic, battery-powered Acoustic, battery-powered

Acoustic, mains-powered

Connection option via potential-free contact

(Accessories: acoustic + optical)

Stackable No No No

Differences from the Basic charging cabinet

Unlike the CEMO Basic 8/20 battery charging cabinet, this version of the smoke detector is mains-powered. However, it also features a power-off switch for smoke detection, a potential-free output on the outside of the cabinet for connection to a fire alarm system, and a 12V connection option for accessories such as a combination alarm (visual and acoustic).

features

In the premium version, the charging cabinet has an alarm, a smoke detector with a potential-free output for an alarm signal and technical ventilation. In the event of heat and/or smoke development, the electrical circuit is interrupted. When the door is opened, the power supply is also interrupted by means of a door contact switch. The doors should therefore always be closed during the charging process.

These are charging variants with 4 horizontally arranged 9-way power strips for power supply. Either with a 230 V version with 1-phase power supply (3500 W / 16 A) or the 400 V version with 3-phase power supply (2x 3500 W / 2x 16 A).

In the premium version, the charging cabinet has an acoustic warning tone, heat dissipation during charging with the aid of the built-in fan and a charging stop in the event of a malfunction or accident. If heat builds up, the circuit is interrupted by means of a de-energised switch. When the door is opened, the power supply is also interrupted by means of a door contact switch. The doors should therefore always be closed during the charging process. In addition, the premium version features an improved connection option for combination alarms (12V) and a connection to a fire alarm system.

Equipped with the CEMO lockEX lock

CEMO lockEX is an innovative mechanism in the door lock that reliably controls the pressure of flammable gases inside the cabinet in order to effectively prevent explosions.

The design is based on an intelligent spring mechanism which, in the event of an explosion of a damaged Li battery, gently opens the cabinet doors to release the pressure and then immediately closes them again securely.

The protection afforded by the property right registered with the German Patent and Trademark Office is particularly important here. It has long been known among experts that lithium batteries can not only cause flames and explosive combustion of individual cells, but that a gas explosion caused by escaping cell vapours is also a possibility. This represents the worst-case scenario for a battery fire, as it can negate the entire protective effect and thus be the most decisive criterion in the risk assessment.

CEMO lockEX combines fire protection and explosion protection in one product and offers a reliable solution for dealing with potentially dangerous battery fires.

The lockEX technology effectively interrupts the course of a battery fire. An explosion can occur even before thermal runaway begins. If the cabinet housing gives way or the doors open, the protective effect can be lost immediately and the burning cells and battery packs are thrown unhindered into the surrounding area at the installation site.

CEMO's lockEX mechanism ensures that the explosion pressure that builds up inside the cabinet is effectively managed. This advanced NO-BANG technology guarantees that the protective effect is maintained without restriction, even in the worst-case scenario of a battery fire.

Tested according to VDMA up to 12 kW/h

The battery cabinet has been tested according to VDMA for lithium-ion batteries. The maximum permissible energy density for this system is 12.0 kWh.

VDMA 24994 is a test standard specifically for fire-resistant storage cabinets designed to safely store lithium-ion batteries. The test checks whether the cabinet can withstand a so-called thermal runaway, i.e. dangerous overheating and self-ignition of the battery. It is important that the cabinet does not emit any flames or toxic gases to the outside and that the door does not open even under pressure. The standard helps companies to significantly increase safety when storing lithium-ion batteries and is considered an important benchmark that is increasingly recognised by manufacturers and insurers.

Well equipped in the event of an accident

Critically damaged lithium-ion cells in particular can pose a serious danger to people and operating equipment in the event of a fire ("thermal runaway"). Dust produced by these fires can settle on circuit boards in production and operating equipment and cause permanent damage. This storage cabinet has MPA-tested fire resistance of over 60 minutes from the inside to the outside in accordance with DIN EN 1363-1. A real battery fire test was carried out with an independent university. The air supply and exhaust openings close automatically in the event of a fire. However, the doors should always remain closed during storage.

Robust construction

The storage cabinet is constructed from robust, fire-resistant components. Special fire protection seals prevent flames from escaping and it has a cold smoke-tight closure system for the openings. The doors are double-leaf and lockable with a sturdy lock and suspension. The door paint finish is orange, similar to RAL 2004, and the body is grey, similar to RAL 7035.

Portable

With the stacking feet, the cabinets can be optimally stored up to a height of 2 units. The stacking feet also make them rollable. Optionally, the cabinet can also be equipped with a fireproof and tested cable entry, for example to connect to the in-house fire alarm system.

Guidelines

There are currently no legal regulations for the storage of lithium batteries/lithium-ion batteries. Only VdS Schadenverhütung GmbH (VdS Risk Prevention Ltd.) provides general safety rules for damage prevention in its publication VdS 3103 : 2019-06 (03). It is advisable to clarify your requirements with your property insurer in advance.

The manufacturer

With imagination and drive, CEMO GmbH from Weinstadt has been synonymous with safe storage for more than 60 years. The company is a pioneer in the field of modern transport and storage container technology and is one of the market leaders in this area.

Future-oriented

Lithium-ion batteries will become indispensable in all industrial applications in the coming years. However, if used improperly, the batteries can pose a potential hazard that should not be underestimated during manufacture, storage and transport. By purchasing this storage cabinet, you are protecting yourself against major financial losses right from the start.

Working for you

Please do not hesitate to contact us if you have any questions. We look forward to hearing from you!

Alarm forwarding: Yes
Fire resistance: 60 min
Fire suppression: Without
Fire test procedure: VDMA 24994
Internal dimensions (mm): 730 x 530 x 1 760
Load function: Yes
Maximum energy density (kWh): 12
Number of doors: 2-leaf hinged
Number of drawers: 0
Number of shelves: 6
Outer dimensions (mm): 890 x 660 x 2 130
Place of deployment: Indoor area
Power supply: 4 rails at 9 x 230 V / 50 Hz
Refractory: Yes
Wardrobe type: Freistehender Schrank
Weight (kg): 267

Downloads

FAQ

Standard security cabinets are designed for indoor use, so they cannot be used outdoors.
The fire protection panels installed in the cabinets contain gypsum, which contains a lot of water, which expands when frozen. This deforms the panels. It can no longer be guaranteed that such a cabinet is still sealed or can withstand an explosion.

If you already have a suitable room that is structurally fire-resistant, then you do not necessarily need a safety cabinet to contain the fire.

However, please do not forget that the damage caused by a battery fire involves immense and also toxic contamination, the disposal of which can quickly lead to high costs.

In addition, you may not be able to continue working as usual until the damage has been finally repaired - depending on the location of the damage.

Accessory

Standard security cabinets are designed for indoor use, so they cannot be used outdoors.
The fire protection panels installed in the cabinets contain gypsum, which contains a lot of water, which expands when frozen. This deforms the panels. It can no longer be guaranteed that such a cabinet is still sealed or can withstand an explosion.

If you already have a suitable room that is structurally fire-resistant, then you do not necessarily need a safety cabinet to contain the fire.

However, please do not forget that the damage caused by a battery fire involves immense and also toxic contamination, the disposal of which can quickly lead to high costs.

In addition, you may not be able to continue working as usual until the damage has been finally repaired - depending on the location of the damage.

Skip product gallery

accessories

CEMO stacking foot set for storage and charging cabinets
CEMO stacking feet set for storage and charging cabinets

Stacking feet set for CEMO storage and charging cabinets. The set consists of 4 metal feet, making the cabinets rollable and stackable in 3 layers. This increases the height by 10 cm. The set comes complete with screws and metal plates to prevent sideways slipping. The set is highly recommended as it greatly improves the handling of the storage and charging cabinets.

Regular price: €82.00
CEMO wireless heat and smoke detector, 2-piece set, battery powered, networkable, including 2 magnetic plates
CEMO wireless heat and smoke alarm, set of 2
battery-operated, networkable, incl. 2 magnetic plates

Networkable smoke alarm (acoustic) in a set of 2. The smoke alarm is included as standard in "Storage" and "Shop Basics".

Regular price: €114.00
CEMO shelf for storage and charging cabinet 8/5 and 8/10
CEMO shelf for storage and charging cabinet 8/5 and 8/10
for floor level or as an intermediate level

Shelf (for base level or as intermediate level)* Dimensions cm (W x D x H): 67 x 40 x 3.5, * Dividers for shelves available on request Ideal for making full use of space and increasing storage area for small-cell lithium batteries

Regular price: €138.00
CEMO fire-resistant cable gland for charging cabinets
CEMO fireproof cable entry for charging cabinets

Additional, fireproof cable entry with a fire resistance of 60 minutes for CEMO storage and charging cabinets. Ideal, for example, for connection to the in-house fire alarm system.

Regular price: €87.00
CEMO aerosol extinguisher (extinguishing potential for 0.25 cbm)
CEMO aerosol extinguisher
Extinguishing potential for 0.25 cubic metres

Aerosol extinguishing agent for lithium batteries, suitable for initial rapid extinguishing and flame suppression, automatic pyrotechnic activation, no maintenance required.

Regular price: €353.00
Label: Charging Cabinet 8/20 Premium with Feet DE
pdf
1409kb
29.01.2026
Product flyer Cemo battery safety
pdf
2857kb
29.01.2026
Product brochure CEMO LockEX 2.0
pdf
1321kb
29.01.2026
Datasheet charging cabinet 8/20 Premium 400 V with stacking feet EN
pdf
1387kb
29.01.2026
Datasheet charging cabinet8/20 Premium with stacking feet EN
pdf
1387kb
29.01.2026
Data sheet charging cabinet 8/20 Premium 400 V with feet DE
pdf
1409kb
29.01.2026
Prototype Certificate CEMO TÜV NORD
pdf
127kb
29.01.2026