- Max. energy density: 4 kWh
- Integrated ventilation system
- Certified as Type 90 in accordance with EN 14470-1
- 10 or 20 230 V sockets
Do you have some questions about this product?
- Your personal contact person
- Name: Petra Fürbeck
- E-Mail: info@lion-care.com
- Phone: +49 (0) 7151 - 256 4817
Technical data
| Alarm forwarding: | Yes |
|---|---|
| Cabinet type: | Freestanding cabinet |
| Charging function: | Optional |
| Fire resistance: | 90 min |
| Fire suppression: | Optional |
| Fire test procedure: | DIN EN 1363-1, DIN EN 14470-1 |
| Max. energy density (kWh): | 4 |
| Number of doors: | 2-leaf hinged |
| Number of shelves: | 2 |
| Outer dimensions (mm): | 1 148 x 591 x 1 241 |
| Place of deployment: | Indoor area |
| Refractory: | Yes |
Product information „PRIOCAB-Li EI90 2-flg. Ladeschrank halbhoch“
PRIOCAB-Li EI90 half-height – charging cabinet for lithium-ion batteries
1. Product overview
The PRIOCAB-Li EI90 half-height is a certified safety cabinet for the storage and, optionally, charging of lithium-ion batteries indoors. The cabinet offers a fire resistance rating of 90 minutes (EI90) from the inside out and is suitable for businesses wishing to store lithium batteries in a controlled, standard-compliant and fire-safe manner.
2. Areas of Use & Application
-
Storage and charging of lithium-ion batteries
-
Suitable for batteries used in e-mobility, power tools, hand tools and industrial applications
-
Suitable for use in workshops, production areas, storage facilities and technical rooms
-
Designed for indoor use under normal environmental conditions
-
Recommendation to consult with insurers in accordance with VdS 3103 (lithium batteries)
3. Technical Specifications – PRIOCAB-Li EI90 half-height
-
External dimensions (W×D×H): 1 148 × 591 × 1 222 mm
-
External dimensions including control unit: 1 148 × 591 × 1 241 mm
-
Internal dimensions (W×D×H): 1,004 × 440 × 904 mm
-
Total weight: approx. 375 kg
-
Shelves: 2 height-adjustable wire mesh shelves
-
Load capacity per shelf: 75 kg (recommended load approx. 70 per cent)
-
Maximum power density per shelf: 2 kW
-
Plinth: wheelchair-accessible, 100 mm high, with removable plinth panel
4. Materials & Construction
-
Casing made from non-combustible building material (building material class A2-s1, d0)
-
Decorative surface with certified fire load insulation
-
High mechanical stability
-
Standard colour: light grey (similar to RAL 7035)
-
Special colours and custom designs available on request
-
Double-leaf doors, opening angle approx. 180°
5. Fire protection and safety features
-
Fire resistance: > 90 minutes (from inside to outside)
-
Perimeter fire-resistant seal, self-foaming in the event of a fire
-
Cold-smoke-tight locking system
-
Pivoting lever lock with double-bit cylinder to prevent unauthorised access
-
Integrated ventilation system with smoke detector and fan
-
Automatic shut-off of ventilation in the event of an incident
6. Charging and connection options
-
Standard cable entry points at the top and bottom
-
Depending on the model, 0–2 power strips, each with 10 sockets
-
Suitable for charging several lithium batteries simultaneously
-
Prepared for additional technology such as sensors or fire alarm integration
-
Optional, mains-independent aerosol fire suppression system available
7. Standards, Testing & Sustainability
-
Fire test in accordance with DIN EN 1363-1
-
Tested in accordance with DIN and EN standards
-
Green building certification in accordance with LEED and DGNB
-
Note: not a self-closing safety cabinet – doors must be kept closed
8. Conclusion
The PRIOCAB-Li EI90 half-height is a professional solution for the fire-safe storage and optional charging of lithium-ion batteries indoors. With its certified EI90 fire protection, robust construction, integrated monitoring and flexible configuration options, the cabinet is suitable for businesses wishing to implement a structured and insurance-compliant risk management system when handling lithium batteries.
9. Working for you
Please do not hesitate to contact us if you have any queries. We look forward to hearing from you!
| Alarm forwarding: | Yes |
|---|---|
| Cabinet type: | Freestanding cabinet |
| Charging function: | Optional |
| Fire resistance: | 90 min |
| Fire suppression: | Optional |
| Fire test procedure: | DIN EN 1363-1, DIN EN 14470-1 |
| Max. energy density (kWh): | 4 |
| Number of doors: | 2-leaf hinged |
| Number of shelves: | 2 |
| Outer dimensions (mm): | 1 148 x 591 x 1 241 |
| Place of deployment: | Indoor area |
| Refractory: | Yes |
Downloads
FAQ
Standard security cabinets are designed for indoor use, so they cannot be used outdoors.
The fire protection panels installed in the cabinets contain gypsum, which contains a lot of water, which expands when frozen. This deforms the panels. It can no longer be guaranteed that such a cabinet is still sealed or can withstand an explosion.
If you already have a suitable room that is structurally fire-resistant, then you do not necessarily need a safety cabinet to contain the fire.
However, please do not forget that the damage caused by a battery fire involves immense and also toxic contamination, the disposal of which can quickly lead to high costs.
In addition, you may not be able to continue working as usual until the damage has been finally repaired - depending on the location of the damage.
Standard security cabinets are designed for indoor use, so they cannot be used outdoors.
The fire protection panels installed in the cabinets contain gypsum, which contains a lot of water, which expands when frozen. This deforms the panels. It can no longer be guaranteed that such a cabinet is still sealed or can withstand an explosion.
If you already have a suitable room that is structurally fire-resistant, then you do not necessarily need a safety cabinet to contain the fire.
However, please do not forget that the damage caused by a battery fire involves immense and also toxic contamination, the disposal of which can quickly lead to high costs.
In addition, you may not be able to continue working as usual until the damage has been finally repaired - depending on the location of the damage.