asecos storage cabinet PRO STORE / ION-PRO-90 (2 doors)
- Max. energy density: 10.425 kWh
- 3-stage alarm system
- Type 90 certified in accordance with EN 14470-1 and VDMA 24994
- Includes pressure relief valve
Do you have some questions about this product?
- Your personal contact person
- Name: Petra Fürbeck
- E-Mail: info@lion-care.com
- Phone: +49 (0) 7151 - 256 4817
Technical data
| Alarm forwarding: | Yes |
|---|---|
| Fire resistance: | 90 min |
| Fire suppression: | Optional |
| Fire test procedure: | VDMA 24994 |
| Internal dimensions (mm): | 1 050 x 522 x 1 647 |
| Load function: | No |
| Maximum energy density (kWh): | 10.4 |
| Number of doors: | 2-leaf hinged |
| Number of drawers: | 0 |
| Number of shelves: | 3, 4, 5, 6 |
| Outer dimensions (mm): | 1 193 x 615 x 1 953 |
| Place of deployment: | Indoor area |
| Power supply: | without |
| Refractory: | Yes |
| Wardrobe type: | Freistehender Schrank |
| Weight (kg): | 484 |
Product information „asecos storage cabinet PRO STORE / ION-PRO-90 (2 doors)“
asecos PRO STORE – Safety Cabinet for Lithium-Ion Batteries with Expanded Warning System
1. Product Overview
The asecos PRO STORE Safety Cabinet from ION-LINE is designed for safe passive storage of lithium-ion batteries. Through an integrated warning system, tested fire resistance, and a robust construction, the cabinet supports a comprehensive safety concept for companies that store lithium batteries in workshops, production areas, or technical rooms.
The cabinet offers over 90 minutes of fire resistance both from outside to inside and from inside to outside and thus meets important requirements in operational fire protection.
Note: The illustrations may differ from the delivered product. The depicted fire suppression system is optional.
2. Areas of Use & Application
-
Passive storage of lithium-ion batteries
-
Use in workshops, industry, and technical areas
-
Organization of larger battery inventories on multiple storage levels
-
Integration into existing rooms without structural alterations
The PRO STORE is designed for safe storage of lithium batteries and features an integrated warning system to monitor potential hazardous situations.
3. Technical Data – asecos PRO STORE
Exterior dimensions (H x W × D): 1953 x 1193 × 615 mm
Interior dimensions (H x W × D): 1647 x 1050 × 503 mm
Empty weight: ca. 484 kg
Maximum total load: ca. 600 kg
Interior equipment
-
3 / 4 / 5 / 6 thermally insulating shelf boards
-
Load capacity per shelf: 75 kg
-
Bottom catch basin made of powder-coated steel sheet
The usable interior dimensions may vary depending on interior configuration.
4. Direct Comparison of Variants
| CORE STORE Battery Cabinet | PRO STORE Battery Cabinet | CORE CHARGE or ION CHARGE Battery Cabinet | PRO CHARGE Battery Cabinet | ULTRA Battery Cabinet | |
| Fire protection | 90 min inside and outside, EN 14470-1, EN 1363-1 | 90 min inside and outside EN 14470-1, EN 1363-1, VDMA 24994 | 90 min inside and outside EN 14470-1, EN 1363-1 | 90 min inside and outside EN 14470-1, EN 1363-1, VDMA 24994 | 90 min inside and outside EN 14470-1, EN 1363-1, VDMA 24994, GS mark: EK5/AK4 22-01 |
| Bottom tray | Integrated bottom tray made of steel sheet | ||||
| Warning system | 1-stage including smoke detector and potential-free contact | 3-stage, including smoke detector, temperature sensor, optical & acoustic alarm, potential-free contact | 1-stage including smoke detector and potential-free contact | 3-stage, including smoke detector, temperature sensor, optical & acoustic alarm, potential-free contact | 3-stage, including smoke detector, temperature sensor, optical & acoustic alarm, relay module with 4 separate potential-free contacts |
| Fire suppression system | Not present | Optional | Not present | Optional | Optional |
| Charging option | Not available | 230V outlets on the shelves / in the lockers | |||
5. Materials & Construction
The safety cabinet is robustly designed for professional use.
-
Sturdy outer cabinet with powder-coated structural surface
-
3-point door suspension
-
Corrosion-protected locking mechanism outside the storage space
-
Shelves made of powder-coated steel sheet
-
Interior finish color: RAL 7035 Light Grey
Integrated leveling feet facilitate placement and compensate for floor unevenness.
6. Fire Protection & Safety Features
The PRO STORE safety cabinet offers an expanded fire protection and safety concept.
-
Fire resistance over 90 minutes
-
Protection from outside to inside according to DIN EN 14470-1 (Type 90)
-
Fire resistance from inside to outside according to DIN EN 1363-1
-
Real-fire test according to VDMA 24994 for Thermal Runaway of lithium-ion batteries
-
Thermally insulating shelves to reduce fire spread
-
Integrated pressure relief vent to controlled pressure release in case of fire
Maximum energy density
-
per storage level: 2.085 kWh
-
in total in the cabinet: 10.425 kWh
7. Ventilation & Technical Equipment
The safety cabinet features an integrated warning and ventilation system.
3-stage warning system
-
Smoke detector
-
Temperature sensor
-
Optical and audible alarm
Optional:
-
Fire suppression system
-
Relay module to differentiate alarm stages
-
Remote alarm module to notify the plant manager
Additionally, the cabinet features a rotating indicator wheel in the exhaust grille that shows the ventilation status.
8. Standards, Tests & Delivery
Certifications
-
DIN EN 14470-1: Fire resistance 90 minutes (Type 90)
-
DIN EN 1363-1: Fire resistance from inside to outside
-
VDMA 24994: Real-fire test for lithium battery thermal runaway
-
CE conformity
Delivery
The delivery of asecos ION-LINE models is to the point of use.
A transport questionnaire is provided before delivery to ensure smooth arrival.
9. Manufacturer – asecos
The manufacturer asecos develops safety cabinets for hazardous substances and lithium batteries. About 300 employees work on solutions for safe workplaces in industry, laboratories, and technical fields.
In addition to development and production, asecos also offers:
-
Maintenance and servicing
-
Technical consulting
-
Support with legal requirements
10. For You in Operation
Please feel free to contact us with any questions.
We look forward to hearing from you!
| Alarm forwarding: | Yes |
|---|---|
| Fire resistance: | 90 min |
| Fire suppression: | Optional |
| Fire test procedure: | VDMA 24994 |
| Internal dimensions (mm): | 1 050 x 522 x 1 647 |
| Load function: | No |
| Maximum energy density (kWh): | 10.4 |
| Number of doors: | 2-leaf hinged |
| Number of drawers: | 0 |
| Number of shelves: | 3, 4, 5, 6 |
| Outer dimensions (mm): | 1 193 x 615 x 1 953 |
| Place of deployment: | Indoor area |
| Power supply: | without |
| Refractory: | Yes |
| Wardrobe type: | Freistehender Schrank |
| Weight (kg): | 484 |
Downloads
FAQ
Standard security cabinets are designed for indoor use, so they cannot be used outdoors.
The fire protection panels installed in the cabinets contain gypsum, which contains a lot of water, which expands when frozen. This deforms the panels. It can no longer be guaranteed that such a cabinet is still sealed or can withstand an explosion.
If you already have a suitable room that is structurally fire-resistant, then you do not necessarily need a safety cabinet to contain the fire.
However, please do not forget that the damage caused by a battery fire involves immense and also toxic contamination, the disposal of which can quickly lead to high costs.
In addition, you may not be able to continue working as usual until the damage has been finally repaired - depending on the location of the damage.
Accessory
Standard security cabinets are designed for indoor use, so they cannot be used outdoors.
The fire protection panels installed in the cabinets contain gypsum, which contains a lot of water, which expands when frozen. This deforms the panels. It can no longer be guaranteed that such a cabinet is still sealed or can withstand an explosion.
If you already have a suitable room that is structurally fire-resistant, then you do not necessarily need a safety cabinet to contain the fire.
However, please do not forget that the damage caused by a battery fire involves immense and also toxic contamination, the disposal of which can quickly lead to high costs.
In addition, you may not be able to continue working as usual until the damage has been finally repaired - depending on the location of the damage.